Air Conditioning & Our Environment

Hydrochlorofluorocarbons

HVAC Environmental

Hydrochlorofluorocarbons, or HCFCs, are chemicals that are mainly used as refrigerants. Unfortunately, releases of HCFCs deplete the Earth’s protective ozone layer.

R-22 is an HCFC refrigerant that is often used in air-conditioning equipment. To protect the Earth’s protective ozone layer, the United States is phasing out R-22, along with other chemicals.

As the phase-out happens, you will need to make informed choices when servicing, repairing, or replacing your existing air-conditioning unit or when purchasing a new unit. EPA has not banned the use or sale of equipment that contains R-22. However, as a homeowner, you need to consider several key factors in your decision to purchase a new unit such as energy efficiency, performance, reliability, cost, and the refrigerant used.

The lengthy phase-out period allows you to replace your air-conditioning equipment that contains R-22 when you normally would; for instance, if it becomes old, inefficient, or ineffective. Realizing that supplies of R-22 will become more limited and the price may increase should also be factors. In the meantime, R-22 remains available for servicing equipment made before 2010.

Choosing an efficient system that uses ozone-friendly refrigerants has important environmental benefits!

Availability and Cost of R-22

  • R-22 is a refrigerant that is often used in air-conditioning equipment
  • Because R-22 Depletes the ozone layer, production and import will be further limited in 2010.
  • In 2020, R-22 will no longer be produced or imported. After 2020, only recovered, recycled, or reclaimed supplies of R-22 will be available.
  • The production (not use) of R-22 is being phased out. You are not required to stop using R-22 air conditioners nor to replace existing equipment.
  • The phase-out period provides time to switch to ozone-friendly refrigerants when you normally would replace your air conditioner.
  • In the future, R-22 supplies will be more limited and costs to service equipment with R-22 may rise.

Servicing Systems with R-22

HVAC Environmental

  • You may continue to have your equipment containing R-22 serviced.
  • The most important thing you can do is to maintain your unit properly. Appropriate servicing minimizes potential environmental damage and maintenance costs.
  • It is important to select a reliable service contractor. Technicians must have EPA Section 608 certification to service equipment containing R-22.
  • Request that Service Technicians locate and repair leaks instead of “topping oft” leaking systems. This protects the ozone layer and saves you money by optimizing performance of your existing equipment.
  • It is illegal to intentionally release any refrigerant when making repairs. Technicians must use refrigerant recovery equipment during service.
  • To use alternative refrigerants in existing equipment, generally the equipment needs to be modified.

Buying a New Air Conditioner

  • Air conditioning systems that use R-22 are still available, and R-22 may be produced for use in newly manufactured equipment until the end of 2009.
  • You may still purchase a system that contains R-22, but supplies of R-22 will be more limited after 2010.
  • Systems that use alternative refrigerants that do not harm the ozone layer are available and will become more common.
  • New energy efficient air conditioners save energy costs. Even if your air conditioner is only ten years old, you may save significantly on your energy costs by replacing it with a newer, more efficient model.
  • Energy efficiency is measured by the seasonal energy efficiency ratio (SEER). The higher the ratio, the more efficient the equipment.
  • A central air conditioner that has earned the ENERGY STAR® label is at least 14% more efficient than a standard new system and can save you money on your cooling bill.
  • ENERGY STAR® qualified systems are available for both R-22 and alternative (R-410A) systems.

Alternative Refrigerants

  • R-4lOA is manufactured and sold under various trade names, including GENTRON AZ-20®, SUVA® 410A.
  • The most common alternative to R-22 is R-410A, a non-ozone depleting HFC refrigerant blend.
  • EPA reviews alternative refrigerants and maintains a list of acceptable substitutes for household and light commercial air conditioning.
  • It is illegal to intentionally release refrigerant substitutes when making repairs. Technicians must take efforts to avoid releases during service.

HCFCs and the Ozone Layer

The stratospheric ozone layer shields the Earth from the sun’s harmful ultraviolet radiation. Emissions of certain synthetic chemicals, including CFCs, halons, and HCFCs, destroy the ozone layer and have created an ozone hole” over the South Pole.

Through the ‘Montreal Protocol on Substances that Deplete the Ozone Layer’, the United States committed to a collaborative, international effort to regulate and phase out ozone-depleting substances. While the US phased out of CFCs and halons in the mid 90’s, we now must first limit HCFC consumption to a specific level and then reduce it in a step-wise fashion.

Phase-Out of R-22 and R142b
HCFC-22 (also called R-22) and l-ICFC-142b are the next two HCFCs that the United States will phase out. The schedule to phase-out HCFCS is:

January 1, 2010
Ban on production and import of HCFC-22 and HCFC-142b except for continuing servicing needs of existing equipment.

January 1, 2015
Ban on sale and use of all HCFCs except for certain uses, including continuing servicing needs of existing equipment.

January 1, 2020
Ban on remaining production and import of HCFC-22CFC-142b
After 2020, the servicing systems with R-22 will rely on recycled or stockpiled quantities.